Remote Monitoring & Control Systems

NPM-R10 Compact

Note:
Powers from 12V or 24V (36V and 48V only monitored)

Monitors:
| 4 Battery voltages (12V -48V)
| External input DC voltage
| Charge current
| Load current
| Ambient temperature
| Mains status
| Tamper alarm

Optional extras:
| 5 Way relay board
| GSM module

Monitoring protocol:
| SNMP V1, V2

View Manual

GSM 232 (Add-On)

Note:
Add-on GSM module (not for standalone use)

Features:
| Control and receive notifications from our devices with RS232 ports 

View Manual

NPM-R10-U

Note:
Powers from 12V to 60V

Features:
| Supports lithium batteries
| 60V input over two wires

Monitors:
| 4 Battery voltages (12V - 60V)
| Charge current
| Load current
| Ambient temperature
| Mains status
| Mains voltage
| Tamper alarm

Optional extras:
| 19" Rackmount bracket
| 5 Way relay module
| GSM module

Monitoring protocol:
| SNMP V1, V2

View Manual

NPM-R10-U-ISO

Note:
Powers from 12V to 60V

Features:
| Supports lithium batteries
| 60V input over two wires
| Non contact clip on DC current sensors

Monitors:
| 4 Battery voltages (12V - 60V)
| Charge current
| Load current
| Ambient temperature
| Mains status
| Mains voltage
| Tamper alarm

Optional extras:
| 19" Rackmount bracket
| 5 Way relay module
| GSM module

Monitoring protocol:
| SNMP V1, V2

View Manual

NPM-R10 RM

Note:
Powers from 12V or 24V (36V and 48V only monitored)

Features:
| Onboard 5 way relay module

Monitors:
| 4 Battery voltages (12V - 48V)
| Charge current
| Load current
| Ambient temperature
| Mains status
| Mains voltage
| Tamper alarm

Optional extras:
| GSM module

Monitoring protocol:
| SNMP V1, V2

View Manual

Dual Battery Bank Controller

Features:
| Auto switch over between battery banks
| Adjust switch over voltage levels in webpage
| Manually select active battery bank in webpage

Monitors:
| Battery bank A voltage (12V - 24V)
| Battery bank B voltage (12V - 24V)
| Load current
| Ambient temperature
| Tamper alarm

Monitoring protocol:
| SNMP V1, V2

View Manual

Environmental Server Room Monitor (ERM-6)

Features:
| Internal battery backup

Monitors:
| Mains status
| Mains voltage
| UPS status
| Internal backup battery voltage
| Smoke
| Water
| Humidity
| Intrusion alarm
| 2 Temperatures

Optional extras:
| GSM module

Monitoring protocol:
| SNMP V1, V2

View Manual

Solar Monitor

Monitors:
| Solar panel input current
| Charge current
| Load current
| Battery voltage (12V - 24V)
| Ambient temperature
| Tamper alarm

Optional extras:
| 5 Way relay board

Monitoring protocol:
| SNMP V1, V2

View Manual

Solar Monitor ISO

Features:
Non contact clip on DC current sensors

Monitors:
| Solar panel input current
| Charge current
| Load current
| Battery voltage (12V - 24V)
| Ambient temperature
| Tamper alarm

Optional extras:
| 5 Way relay board

Monitoring protocol:
| SNMP V1, V2

View Manual

TCPIP V/A Meter

Note:
Powers from 12V or 24V (36V and 48V only monitored)

Monitors:
| 4 Battery voltages (12V - 48V)
| Charge current

Monitoring protocol:
| SNMP V1, V2

View Manual

3 Phase AC Monitor

Power input:
| Powers from 12V or 24V DC

Monitors:
| Connected battery voltage
| 3 Phase AC Voltage (110V - 220V)

Monitoring protocol:
| SNMP V1, V2

View Manual

AC Energy Monitor

Power input:
| Powers from 12V or 24V DC

Monitors:
| Connected battery voltage
| AC Voltage (110V - 220V)
| AC Current (0A - 15A)
| Wattage

Monitoring protocol:
| SNMP V1, V2

View Manual

DC Energy Monitor

Power input:
| Powers from 12V or 24V DC

Monitors:
| DC voltage (input)
| DC current

Monitoring protocol:
| SNMP V1, V2

View Manual

NPM-R10 Lite

Monitors:
| 2 Battery voltages (12V -24V)
| Charge current
| Load current
| Ambient temperature
| Mains status
| Tamper alarm

Optional extras:
| 5 Way relay board

Monitoring protocol:
| SNMP V1, V2

View Manual

Ethernet Dual AC Monitor

Features:
| Onboard relay can be toggled via webpage
| Select relay mode (latch or toggle) with onboard jumper

Monitors:
| 2 Mains status
| Battery voltage (12V - 24V)

Monitoring protocol:
| SNMP V1, V2

View Manual

Ethernet AC Monitor + Email

Features:
| Onboard email notifications
| Set battery alert levels in webpage

Monitors:
| Mains status
| Battery voltage (12V -24V)

Monitoring protocol:
| SNMP V1, V2

View Manual

Ethernet Dual Relay

Features:
| 2 Relays
| Select relay mode (latch or toggle) with onboard jumper
| Control relays via webpage or SNMP set commands

Monitors:
| Battery voltage (12V - 24V)

Monitoring protocol:
| SNMP V1, V2

View Manual

Ping Watchdog

Features:
| Toggle relay automatically when ping to IP address failed
| Set ping intervals and timeout in webpage

View Manual

Network IO Board

Note: 
Powers with 12V

Features:
| 8 digital (potential free) inputs
| 8 Relay outputs
| Control relays from webpage
| View (220V) mains status, battery voltage, inputs status and relays status in webpage

View Manual

Wireless mA Link

Note: 
Powers with 12V - 24V

Industry standard 4-20mA output on unit B

One digital input and one Relay output on each unit

Lora modules with 866Mhz Omni antennas ensures long range non-line of sight communication

View Manual

Wireless Digital Link

Note: 
Powers with 12V - 24V

One digital input and one Relay output on each unit

Lora modules with 866Mhz Omni antennas ensures long range non-line of sight communication

View Manual